XN-3100

The XN-3100 configuration includes two XN analysis modules and a high-quality, fully integrated slide maker and stainer module, our SP-50 unit. This offers great productivity while taking up minimal space. The XN-3100 also has the excellent Extended information-processing unit (IPU) on board as standard that can intelligently route and control your sample and data workflow.

If you have a medium-sized lab with a fair smear rate, you will appreciate the detail in the XN-3100 set-up. Because the two analysis modules process rack samples simultaneously, it can accommodate any sample without slowing down – the modules work together perfectly. And you don’t lose any precious time, even with abnormal samples. Additionally, depending on the workload of your smears, you can choose the configuration you would like to install. The Standard version provides 30 slides/h. The high-throughput version provides 75 slides/h.

The XN-3100 has a single point of entry and a single point of exit. Reflex testing occurs within the same loop, and before samples pass the SP-50 module. Sample racks are then sent to the SP-50 module where the samples needing a smear are removed. Like extended measurements, smears are only initiated if they offer additional diagnostic value. The analysis profile is extended automatically to include smear-making and staining, but you may also order this up front, for instance with known special samples.
 

Technical Specifications

Measurement principles

WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin

Aspiration volume 

XN module: 88 µL in whole blood (WB) mode and body fluid (BF) mode
SP-50 module: 70 µL for smear preparation in auto mode, 38 µL for smear preparation in manual mode

Throughput

Two modules of XN-10/20 in combination with SP-50 (S or H):

  • up to 200 samples/h in whole blood (WB) mode,
  • up to 40 samples/h in body fluid (BF) mode per module,
  • up to 30 slides/h in standard mode,
  • up to 75 slides/h with the optional high-throughput licence

Quality control

XN Check (three levels) and XN Check BF (two levels)

Parameters

 

XN-CBC (always with NRBC) & XN-DIFF (always with IG)

Whole Blood

WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#

With RET (optional)    

RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)      

PLT-F, IPF, IPF#

With WPC (optional)

Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#

XN Stem Cells licence

HPC%, HPC#

Body Fluids with XN-BF    

WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#
(optional)

Contacts
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Nordic ApS

Hedegaardsvej 88

2300 Copenhagen S

Denmark

+45 70 20 45 01

Training

New XN-Series (9100/3100/1500) operation basic video training

This course is addressed to lab technicians and operators of the Sysmex XN-Series in a haematology lab.

Sysmex Academy

 

New XN-Series (9100/3100/1500) maintenance basic video training

This course is addressed to lab technicians and operators of the new Sysmex XN-Series in a haematology lab.

Sysmex Academy

Documents

Product documents

Safety data sheets

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

BT-50

BT-50

Barcode terminal with added innovative functionalities – for XR-9000 automation lines

Details
CellaVision HemaPrep®

CellaVision HemaPrep®

Semi-automated preparation of up to two peripheral blood smears

Details
CellaVision DC-1

CellaVision DC-1

CellaVision® DC-1 - Digital cell morphology

Details
Copyright © Sysmex Europe SE. All rights reserved.